Endura AZ20/AZ25 Oxygen Monitor Combustion gas analysis

ABB 氧化鋯分析儀 AZ25 AZ20 產(chǎn)品簡介

 

Introduction

The Endura AZ20 is the latest in a long line of high-quality, combustion gas analyzers from ABB.

The sensor, based on a zirconium oxide cell, is mounted at the tip of the probe that is inserted in the flue duct. The resulting direct, in situ measurement provides accurate and rapid oxygen reading for combustion control / optimization and emissions monitoring purposes.

Endura AZ20 has been designed for extended periods of maintenance-free operation. The modular design with reduced component count improves the reliability and robustness of the system and simplifies breakdown repair if it occurs.

Kits containing all the parts needed to complete on-site repairs are available from ABB, ensuring that service personnel can effect repairs quickly and efficiently at minimum cost. The Endura AZ20probe has retained an easy-access cell arrangement, similar to the proven ZFG2 probe. This ensures cell replacement can be carried

out on-site using readily available, basic hand tools, even after long periods of high temperature operation.

The Endura AZ20 oxygen probe measures oxygen concentration in flue gas using an in situ 'wet analysis' method. The 'wet analysis' method avoids measurement error (typically20% of reading higher than the actual value) that is introduced by a sampling system using the 'dry analysis' method.

For customers with an existing installed ZFG2 probe with a ZMT or ZDT transmitter, a 55 V heater version of the Endura AZ20probe (the Endura AZ20 / ZFG2 replacement probe) is available.

System equipment comprises a (flue-mounted) Endura AZ20probe controlled by an integral or remote transmitter. During operation, a zirconia cell within the probe is held at a constant temperature of 700°C (1292 °F) by a probe heater and control

thermocouple assembly. If the heater control circuitry or software fails (unsafe), the probe heater power supply is switched off, ensuring the system fails 'safe' and protects the heater from an over-temp failure.

An output generated at the zirconia cell is processed in the transmitter giving a locally displayed O2 reading and a 4 to 20mA retransmission signal over any range between 0 % and 100% O2.

Optional automatic calibration (AutoCal*) enables automatic,semi-automatic or manual calibration to be performed using a probe-mounted gas control manifold mounted within the probehead. Calibration sequencing is software-controlled from thetransmitter.

Optional restrictors (where fitted*) in the probe head control thetest gas and reference air flow without the need for flowmeters.The probe requires only preset test gas and reference airpressures of 1 bar (15 psi) to maintain a constant flow of 2.2 l /min (4.662 scfh). This flow is not affected by changes in themeasured gas pressure of ± 0.35 bar (5 psi). 

Introduction

The Endura AZ25 combustion oxygen analyzer is the latest ina long line of high-quality, combustion gas analyzers fromABB. The AZ25 is designed to measure oxygen concentrationin high temperature furnace atmospheres.

The sensor, based on a zirconium oxide cell, is mounted at thetip of the probe that is inserted directly into the furnace. Theresulting direct, in-situ measurement provides an accurate andrapid oxygen reading, for combustion control / optimizationand process quality control purposes.

The in-situ technique provides a true oxygen measurementinside the process. It eliminates 'equilibrium shift' that iscommon to systems in which gas samples are extracted andcooled before measurement.

Reference air (500 to 1000 ml/min [1 to 2 ft3/hr]) is required foraccurate operation and can be supplied from an ABBmains-powered pump unit or a flow regulator unit.

 

Unique integrated automatic calibration

The Endura AZ25 automatic calibration system eliminates theneed for the expensive ancillary equipment required forautomatic calibration on traditional flue gas oxygen analyzersystems. ABB’s fully integrated, automatic calibration feature

controls the test gas sequence and detects test gasavailability, eliminating incorrect calibrations due to loss of testgas. Integrated automatic calibration secures the oxygenmeasurement, providing complete confidence in the analyzer's

 

performance.

Long-term operation without technician intervention minimizesoperating costs, total cost-of-ownership and optimizes systemaccuracy. A significant proportion of service visits to ananalyzer result in 'no fault found'. Endura AZ25's high-quality

manufacture, advanced diagnostics and automatic calibrationis targeted at reducing this wasted effort and cost.

 

Dependable

— measurement of O2 in a wide variety of processes

— virtually instantaneous response

— resistance to sulphurous reducing atmospheres

 

Versatile

— 600 to 1250 mm (2 to 4 ft) lengths

— choice of protective sheath materials

— integral thermocouple for automatic temperature

compensation

— high temperature operation up to 1400 °C (2552 °F)

 

Low cost-of-ownership

— in situ measurement

— no sampling system required

— automatic calibration functionality as standard

— optional automatic calibration hardware

Applications

— Furnace atmosphere monitoring:

— Annealing furnace

— Sintering of metals

— Ferrite sintering

— Whiteheart malleablizing

— Combustion measurement and control in:

—Soaking pits

—Process heaters

—Fluidized bed boilers

—High temperature incinerators

— All other combustion processes where the flue gastemperature is in excess of 600 °C (1112 °F)

 

Aluminous porcelain

Entry level sheath material suitable for applications withtemperatures up to 1250 °C (2282 °F) – limited resistant tocorrosive chemicals and mechanical and thermal stress.

Recrystallized alumina

Suitable for applications with temperatures up to 1400 °C(2552 °F) resistant to corrosive chemicals and more severemechanical and thermal stress are present.

Incoloy 800

Suitable for applications with temperatures up to 850 °C

(1562 °F) when mounted horizontally and up to 1000 °C

(1832 °F) when mounted vertically.

Offering limited resistance to corrosive chemicals and resistantmechanical and thermal stress.

愛澤工業(yè)(IZE_INDUSTRIES)銷售型號(hào)示例:

ABB 氧化鋯分析儀AZ25/.1.1.2.1.1.5.3.1.2.0.0.0.0 /STD

ABB 氧化鋯分析儀AZ25/.1.1.2.1.1.5.1.1.1.1.0.0.0.0

ABB 氧化鋯分析儀AZ25/.1.1.2.1.1.5.1.1.1.1.0.0.0.0.E./STD

ABB 氧化鋯分析儀AZ25/.1.1.2.1.1.5.3.1.2.0.0.0.0.E.Z.J/STD

ABB 氧化鋯分析儀AZ20/112112225111100C/STD

ABB 氧化鋯分析儀AZ20/1.2.2.2.1.2.2.3.3.7.1.1.2.E

ABB 氧化鋯分析儀AZ20/222122337112E

ABB 氧化鋯分析儀AZ20/2.2.2.1.2.2.3.3.7.1.1.21.0.0.E/STD

ABB 氧化鋯分析儀AZ20/222122337112E/STD

 

如果您有任何關(guān)于產(chǎn)品的相關(guān)技術(shù)咨詢或者需要產(chǎn)品的相關(guān)技術(shù)資料與文檔,請(qǐng)隨時(shí)愛澤工業(yè),或者訪問我們將盡全力解決您的問題。

If you have any question, please feel free to dial or browse our website. Thank you.

主站蜘蛛池模板: 精品国产欧美 | 一区二区三区四区在线 | 亚洲欧美日韩一区二区三区四区 | 特黄网站 | 日韩精品免费在线观看 | 黄视频在线播放 | 国产成人精品一区二 | 欧洲精品一区二区 | 日韩av网站在线观看 | 国产欧美一区二区三区在线看蜜臀 | 国产无遮挡又黄又爽免费网站 | 亚洲欧洲天堂 | 国产三级做爰高清在线 | 国产免费自拍视频 | 中文字幕高清在线 | 91们嫩草伦理| 欧美综合激情 | 国产永久免费视频 | 欧美国产一区二区 | 欧美国产在线视频 | 亚洲欧美另类图片 | 青青伊人网 | 黄www| 国产美女永久免费无遮挡 | 国产无遮挡又黄又爽又色 | 91一级片 | 4438成人网 | 永久在线 | 日韩在线播放视频 | 毛片网页| 亚洲一区二区av | 一级黄色片网站 | 日韩高清精品免费观看 | 色综合天天综合网国产成人网 | 三级视频在线观看 | av片免费看 | 欧美色综合网 | 免费的毛片 | 亚洲性生活片 | 69精品视频 | 九九精品免费视频 |